Remko WPM-Smart-Control-Manual for specialists-WKF-120 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Hardware Remko WPM-Smart-Control-Manual for specialists-WKF-120. REMKO WPM-Smart-Control-Manual for specialists-WKF-120 User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 100
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Operating manual
Read the instructions prior to performing any task!
REMKO Smart WP MANAGER
Smart Control for WKF 120/180 and WKF 120/180 Duo
Manual for experienced specialists
0094-2014-10 Edition 1, en_GB
Vista de página 0
1 2 3 4 5 6 ... 99 100

Resumo do Conteúdo

Página 1

Operating manualRead the instructions prior to performing any task!REMKO Smart WP MANAGERSmart Control for WKF 120/180 and WKF 120/180 DuoManual for e

Página 2

Overview of the menus (User level)LEVEL 03D houseHot water Room climate..LEVEL 1Information SettingsChimneysweep *)LEVEL 2BasicinformationSolarDomesti

Página 3 - Table of contents

ConsultingThanks to intensive training, our consultants are always completely up-to-date in terms of technical knowledge. This has given us the reputa

Página 4

"3D house" animationOnce the Smart Control commissioning wizard hasbeen completed, you will see the home screen withthe 3D house. Pressing t

Página 5

Explanation of operating modes:Standby - the controller waits for the next requestDispensing operation - hot water is being dis-pensedCirculation - ci

Página 6

Favourites menu: for the userUsing the rotary knob (turning it clockwise) you canaccess other views. They allow you to rapidly andeasily adjust the mo

Página 7 - Basic settings

One-off hot water / party modeActivating Party mode (select with the rightsoftkey) causes the next window of time withreduced heating to be disregarde

Página 8

Solar yieldTime periodHistoryFig. 24: Solar yieldsNOTE:These yields are also displayed with an activatedPV functionThen turn the rotary knob clockwise

Página 9 - Operation - User level

"Main menu" menu itemPressing the Menu key takes you to the main menu. There is an expert mode and a user mode. The twoauthorisation levels

Página 10 - REMKO Smart WP MANAGER

"Information" menu item - UserThis menu contains information about the current operating status of the system. The menu is opened withthe

Página 11 - Next viewStart animation

"Information" menu item (continued) - UserAuthorisa-tion levelLevel 2menu itemLevel 3 menu item InfoSolarPump A01You can findmany of the i

Página 12

"Information" menu item (continued) - UserAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item InfoCoolingCooling cycle set temp.You can

Página 13

Translation of the original operating manualRead these operating instructions carefully before commis-sioning / using this device!These instructions a

Página 14

"Information" menu item (continued) - UserAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item InfoHeat pump(I/0 2)Only WKF DuoHeat pump

Página 15 - Time period

"Information" menu item (continued) - UserAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item InfoMeter read-ingsSolarCurrent outputYou

Página 16

"Information" menu item (continued) - UserAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item InfoMeter read-ingsPhotovoltaicPhotovoltai

Página 17

"Settings" menu item - UserIn this menu you can configure the settings. For example, you can adjust hot water and heating tempera-tures or

Página 18

"Settings" menu item (continued) - UserAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Level 4 menu item InfoHeating /coolingModeRoo

Página 19 - Short-term heating offset

"Settings" menu item (continued) - UserAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Level 4 menu item Info3rd mixedHeating cycle(

Página 20

4 Operation - Expert level 4.1 General notes regarding themenu structure of the controller The following information is primarily directed at

Página 21

Overview of the menus (Expert level)LEVEL 03D houseHot water Room climate..LEVEL 1Information SettingsChimneysweep *)LEVEL 2BasicinformationSolarDomes

Página 22

4.2 Commissioning wizard The commissioning wizard which starts when thecontroller is activated is intended for programmingthe controller for use on

Página 23

Setting the countrySelect the country with the rotary knob and confirmthe entry with "OK".Fig. 31: Selecting a countryMenu item ParameterFac

Página 24

Table of contents1 Safety and usage instructions...

Página 25

Menu item ParameterFac-tory settingPolskiČeštinaPress "Next".Setting the time zone for the winter timeSelecting the time zone for the winter

Página 26

Software updateWhen first installing the controller this parameter isconfirmed with "NO".If a new software status is installed after the ini

Página 27 - Error messages

Domestic hot-water heatingOptionally, you can activate or deactivate the"Domestic hot-water heating" function. ActivateDomestic hot-water he

Página 28

Hot water circulationIf there is a hot water circulation pump in thebuilding, which you are intending to operate in anenergy-saving manner using the c

Página 29

Impulse-guided circulation -Running time of the circulationSwitch-on time of the circulation pump after a dis-pensing impulse.If the circulation line

Página 30

Unmixed heating cycleOptionally, you can activate or deactivate the"Unmixed heating cycle" function. Activate the"Unmixed heating cycle

Página 31

Setting the heating curve:- Activate the base point with the right softkey, setwith the rotary knob and conform with the rightsoftkey.Fig. 49: Settin

Página 32

Standard inlet temperature:the standard inlet temperature corresponds to theset temperature of the heating water at thestandard outside temperature in

Página 33

2nd mixed heating cycleActivate if a heating cycle with radiators isinstalled. (select with the rotary knob and confirmwith "OK")Fig. 57: Ac

Página 34

Fig. 60: Setting the standard inlet temperatureFig. 61: Set the standard outside temperatureFixed-value-control heating cycle modeSpecify the set temp

Página 35

1 Safety andusage instructions 1.1 General safety notes Carefully read the operating manual before com-missioning the units for the first time.

Página 36

Standard inlet temperature:the standard inlet temperature corresponds to theset temperature of the heating water at thestandard outside temperature in

Página 37

4th mixed heating cycle (only WKF Duo)Activate if a heating cycle with radiators isinstalled. (select with the rotary knob and confirmwith "OK&qu

Página 38

Fig. 70: Setting the standard inlet temperatureFig. 71: Set the standard outside temperatureSystem separationActivation if a mixed heating cycle is se

Página 39

Setting the building time constantThe building time constant specifies the ability of the building to retain heat. The building constant isdependent u

Página 40

Cooling functionActivate (select with the rotary knob and confirmwith "OK") if the building is to be actively cooledwith the heat pump in su

Página 41

Selecting the pump systemSelect the pump system for the speed controlsystem (select with the rotary knob and confirmwith "OK"). The speed co

Página 42

Medium flow rate probeThe amount of heat delivered from solar yields isrecorded continuously, and can be called up in theform of a daily or cumulative

Página 43

Heat carrier mediumSelect (select with the rotary knob and confirm with"OK") the type of solar fluid used, in order to calcu-late the amount

Página 44

Acquisition of the stored energy via the S 09probeIf heating is to be provided from the available solaryield (if required), this parameter must be act

Página 45

4.3 Template hydraulic diagrams with installation parameters NOTICE!The following template hydraulic systems are only to be used as a planning aid

Página 46

1.6 Safety notes for the operator The operational safety of the units and compo-nents is only assured providing they are used asintended and in a f

Página 47

Menu item Parameter Factory setting WKFWKFDuoControl panel address Control panel 1-3 Control panel 1 X XCountry Deutschland - Slovensko Deutschland X

Página 48

Menu item Parameter Factory setting WKFWKFDuo3rd mixed heating cycle Activated / Deactivated Deactivated - XHeating cycle mode Heating curve Deactivat

Página 49 - 1 F2 F3 F4

Hydraulic diagram for heat pump assembly WKF FrankfurtFunctions: heating and hot water, operating mode: monoenergetic or bivalent alternative. Solar p

Página 50

Menu item Parameter Factory setting WKFWKFDuoOperating modeMonoenergetic/bivalent alternativeMonoenergetic X XDom. hot-water heating Activated / Deact

Página 51

Menu item Parameter Factory setting WKFWKFDuo4th mixed heating cycle Activated / Deactivated Deactivated - XHeating cycle mode Heating curve Deactivat

Página 52

Hydraulic diagram for heat pump assembly WKF Frankfurt SolarFunctions: heating/hot water and solar, operating mode: monoenergetic or bivalent possible

Página 53

Menu item Parameter Factory setting WKFWKFDuoActivate heat pump Activated / Deactivated Activated X XOperating modeMonoenergetic/bivalent alternativeM

Página 54

Menu item Parameter Factory setting WKFWKFDuo4th mixed heating cycle Activated / Deactivated Deactivated - XHeating cycle mode Heating curve Deactivat

Página 55

4.4 Menu structure of the controller "Information" menu item - ExpertThis menu contains information about the current operating status

Página 56

"Information" menu item (continued) - ExpertAuthorisa-tion levelLevel 2menu itemLevel 3 menu itemLevel 4 menuitemInfoBasic infor-mation (c

Página 57

1.11 Transport and packaging The devices are supplied in a sturdy shipping con-tainer or inside the heat pump casing. Pleasecheck the equipment imm

Página 58

"Information" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Info1st unmixedHeating cycleHeating cycl

Página 59

"Information" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item InfoCoolingChangeover valve A14You can f

Página 60

"Information" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item InfoHeat pumpHeat pump statusYou can fin

Página 61

"Information" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item InfoHeat pump(I/0 2)Only WKF DuoHeat pum

Página 62

"Information" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Level 4 menu item InfoMeter read-ingsSol

Página 63

"Information" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Level 4 menu item InfoMeter read-ingsHou

Página 64

"Information" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item InfoChecklistCollector temp. S01You can

Página 65

"Settings" menu item - ExpertIn this menu you can configure the settings. For example, you can adjust hot water and heating tempera-tures

Página 66

"Settings" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Level 4 menu item InfoBasic settings System

Página 67

"Settings" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Level 4 menu item InfoSolarCollectorMax. te

Página 68

Pressing the Info key (6) delivers information andsupport at any time on the area currently selected.Pressing the Menu key (7) takes you to the mainme

Página 69

"Settings" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Level 4 menu item InfoHot waterDomestic wat

Página 70

"Settings" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Level 4 menu item InfoHeating /coolingBuild

Página 71

"Settings" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item InfoSolar heatingExcessive temperature in t

Página 72

"Settings" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Info2nd mixedHeating cycleHeating cycle mod

Página 73

"Settings" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Info4th mixedHeating cycle(I/0 2)Only WKF D

Página 74

"Settings" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menuitemLevel 3 menu item Level 4 menu item InfoHeat pumpBasic settin

Página 75

"Settings" menu item (continued) - ExpertAuthorisa-tion levelLevel 2 menu item Level 3 menu item Level 4 menu item InfoHeat pump cont.Outp

Página 76

"Settings" menu item output restriction(night mode with noise optimisation)Fig. 90: "Output restriction" menu itemUnder the leve

Página 77

Fig. 96: Output restriction cooling (reduced)The output restriction in "reduced" cooling mode(22:00 - 06:00 hrs) is set to 90% in the factor

Página 78

"Chimney sweep" menu item - ExpertAuthorisa-tion levelLevel 2 menu item Level 3 menu item InfoMode Normal operation / test mode You can fi

Página 79

Language / TimeZurück 1/6OKGrundeinstellungenBasic settingsBackFig. 7: Language / TimeSelecting a parameterPress the rotary knob until you reach the &

Página 80

"Messages" menu item - ExpertPressing "OK" (right softkey) takes you to submenus of the menu item "Messages".This is w

Página 81

"Message" menu item (continued) - ExpertManual mode (relay test) (continued) Parameter Selection parameter Pump 2nd mixed heating cycl

Página 82

"Message" menu item (continued) - ExpertManual mode (relay test) (continued) Parameter Selection parameter Close mixer 2nd mixed heatin

Página 83

"Message" menu item (continued) - ExpertManual mode (relay test) (continued) Parameter Selection parameter Pump indoor unit (top) Outp

Página 84

"Message" menu item (continued) - ExpertManual mode (probes) (continued) Parameter Selection parameter 4th mixed heating cycle inlet te

Página 85

"Message" menu item (continued) - ExpertManual mode (probes) (continued) Parameter Selection parameter Heat generator return temperatu

Página 86

5 Assembly 5.1 Room installation of theSmart-Control NOTICE!Only use the unit in dry areas and protect itfrom electromagnetic radiation.The Sma

Página 87 - Electrical wiring

6 Electrical wiring 6.1 Electrical configuration - I/0 module 01 Use wire gauge corresponding with the connection cable supplied!Lay load lines

Página 88

6.2 Terminal assignment / legend - I/0 module Terminal assignment I/0 module 01Designation Input Output Signal DescriptionPower X Power supply

Página 89

Designation Input Output Signal DescriptionA11.1 X Changeover valve 2nd WE Smart BVTA12.1 X Not connectedA13.1 X 2nd mixed heating cycle p

Página 90

3 Operation - User level 3.1 Menu structureof the controller The following information is primarily directed atsystem operators. Specialists ca

Página 91

6.3 Electrical configuration - I/0 module 02 Use wire gauge corresponding with the connection cable supplied!Lay load lines separately to measuring

Página 92

6.4 Terminal assignment / legend - I/0 module Terminal assignment I/0 module 02Designation Input Output Signal DescriptionPower X Power supply

Página 93 - PV power utilisation

Designation Input Output Signal DescriptionA12.2 X Not connectedA13.2 X 4th mixed heating cycle pump (230V) switchedA14.2 X Not connectedA

Página 94

7 PV power utilisation 7.1 Higher energy consumptionfrom the combination of heatpump and PV plant Ideal for new and existing photovoltaic plants

Página 95 - Systems with a

7.2 Using the PV power surplus The self-generated photovoltaic power is used inthe first instance for power needs in the home(lighting, household a

Página 96

7.3 Systems with aphotovoltaic plant SystemsThe smart heating function can be used with thefollowing variants:n Hybrid heat pumpn Split air/water h