Edition GB - W10REMKO WLTWLT 25, WLT 27, WLT 45, WLT 55, WLT 75, WLT 85Chilled water wall unitsOperation · Technology · Spare parts
SWING keyThe "SWING" key enables the swinging or locking of the oscillating fins. This improves the distribution of the cooled air inside the
TIMER KEYThe "Timer" keys are used for programming a switch-on or switch-off delay. If the air conditioning unit should be switched on with
ShutdownTemporary shutdown1. Let the unit run for 2 to 3 hours in circulation mode, or in cooling mode at maximum temperature, to extract any residua
Cleaning the housing1. Disconnect the power supply to the unit.2. Open and fold the intake grill on the front side upwards.3. Clean the grill and h
Troubleshooting and customer serviceThe unit and components are manufactured using state-of-the-art production methods and tested several times to ver
OPERATIONOPERATING MODE Possible cause Remedial measuresRed Mains voltage available Normal operating conditionRed Red Heating mode Normal operating co
InstallationConnection of medium pipings The connection of the lines by the customer takes place on the angled side of the unit. For the purpose o
The control is implemented through the 3-way valve assembly. It comprises the electrically actuated valve head and the valve body. If the head is elec
Electrical wiringAll electrical installation work is to be performed by specialist companies. Disconnect the power supply when connecting the electric
Leak testingOnce the connection has been made successfully, the leak test is carried out.1. Flush the system twice with tap water.2. Clean the sieve
Function test of heating operating mode1. Switch the power supply on.2. Open all shut-off valves.3. Switch on the heating system and the correspond
Cooling capacityMedium inletMedium nominal5 °C 7 °C 9 °C 11 °C 13 °CCooling capacityFlowvolume[m3/h]Pressure loss[kPa]QK[kW]QS[kW]QK[kW]QS[kW]QK[kW]QS
Technical dataSeriesWLT 25 WLT 27 WLT 45 WLT 55 WLT 75 WLT 85Operating modeChilled water wall unit for 2-pipe systemNominal cooling capacity 1)kW 2.04
Spare parts listNo.Description WLT 25 WLT 27 WLT 45 WLT 55 WLT 75 WLT 851 Air inlet guard1105750 1105765 1105772 1105772 1105790 11057902 Circulating
We reserve the right to make technical changes and provide no warranty as to the accuracy of this data!ConsultationThanks to intensive training, our c
ContentsRead these operating instructions carefully before commissioning / or using the system.These instructions are an integral part of the unit an
Safety notesEnvironmental protection and recyclingDisposal of packagingAll products are packed for trans-port in environmentally friendly materials. M
Transportation and packaging System configurationSystem descriptionThe unit is designed for a 2-conductor system. The system has 2 medium pipes (condu
Infrared remote controlThe infrared remote control sends the programmed settings a distance of up to 6 m to the receiver of the unit (fig. 1, page 7).
Keys on the remote control "ON / OFF" keyActuate the key to switch the unit on. The POWER indicator for the unit illuminates "FAN&qu
Key functionsTo enter the circulation mode, actuate the "MODE" key once or several times until the FAN indication is shown in the display. I
The heat exchanger cools the air below its dew-point due to the low inlet temperature - this results in the airborne humidity being condensed out. The